# Rev A release gates - NOT RELEASED FOR FABRICATION OR OCCUPIED USE

This package is a reproducible engineering foundation and simulated demonstration. It is not a production release. A valid CAD solid and plausible animation do not qualify an occupied product.

| Gate | Current state | Evidence needed before release |
|---|---|---|
| CAD solids and STEP exchange | Script checked; fixed structural contact graph connects to Z0 floor pads; see validation.json | Independent CAD review, all interfaces and production tolerances; contact is not joint strength |
| Motion clearance | Sampled exact-solid checks only | Continuous swept volumes, all-pair linkage/frame checks, probes, cables and deformable upholstery |
| Actuator integration | Envelope / load screening | Exact supplier configuration, eye lengths, clevis sizes, stroke, duty, noise, brake/holding and mounting-load data |
| Recliner holding and recovery | OPEN | Independent holding / brake selection; stop contact design; loaded failure and no-power recovery test |
| Door operating force / release | OPEN | Full-width slat/track prototype, selected springs, force <=applicable limit, anti-jam / fail-open recovery inside and outside |
| Pinch/crush guarding | OPEN | Finger-probe and trap analysis, guard CAD, hardwired hold-to-run/safe-stop, fault testing |
| Tray latches / emergency stow | OPEN | Final latch and spring release; 15 lb edge loading, misuse, release with load and no power |
| Storage and legrest interlock | Demo sequence only | Physical interlock or relocation; retention and clear-entry checks |
| Structural 300 lb rating | Ideal hand calculations only | Licensed engineer joint/shaft/frame review, weld procedures, fatigue and supervised load/stability tests |
| Accessibility | NOT established | Accessibility specialist + VCU layout review; clear widths/depths/heights, route, reach, transfer, operating force and companion configuration |
| Fire and roof / sprinklers | BLOCKS INSTALLATION | VCU facilities/building/fire official classification, accepted sprinkler/alarm protection and complete material/product fire evaluation |
| Ventilation | Combined heat case exceeds assumed 3K comparison at 25 L/s; no approved minimum | Revise fan/duct and heat placement; occupancy category, room Class 1 air and outside-air design, fan curve, installed flow/CO2/temp/draft tests |
| Electrical / battery | Placement and energy estimate | Exact listed components, safety circuit and wiring design, BMS/charger/protection, fault, thermal and product safety tests |
| 10 dB noise reduction | UNTESTED; high risk | Repeatable calibrated test with fan on and white noise off, duct/door redesign if needed |
| Upholstery / finishes | Candidates only | Actual complete construction flame/smoke evidence, cleaning compatibility and replacement specification |
| Cleaning | Procedure proposed | Timed cleaning; label contact-time compliance and repeated exposure checks |
| Viewer | Node/static and cross-language tests | Browser/runtime, touch and performance QA on intended desktop/tablet hardware |
| Commercial manufacturing | Preliminary drawings / budget | Supplier DFM, dimensions/interfaces and tolerance stack-ups, RFQs, QA plan and independent design review |
| GitHub repository | Initial private upload VERIFIED; original four commits preserved | See revisions/REMOTE_VERIFICATION.json; recheck private visibility before every subsequent remote write and verify the new head |

No suppliers have approved this design. No FEA, CFD, certified test, acoustic result, physical prototype, installation approval or product certification is claimed.